2X31m Aerated Concrete Brick Autoclave with Triple Safety Interlocking Protection
Price: |
US $ 80000-90000/Piece |
Min Order: |
1/Piece |
Pay Type: |
L/C,T/T,Western Union,Paypal |
Product Specifications
Prod Model: |
SN-ZGF20310 |
Design Pressure: |
1.6 MPa (16 Bars) |
Working Pressure: |
1.5 MPa (15 Bars) |
Design Temperature: |
204 ºC |
Working Temperature: |
201 ºC |
Shell Thickness: |
16mm |
Structure: |
Horizontal |
Door Mode: |
Single or Double |
Certification: |
GB/Ce/PED/ASME |
Insulation Mode: |
External |
Insulation Material: |
Rock Wool |
Pressure Level: |
Low Pressure (',0.1MPa≤p<1.6MPa) |
Condition: |
New |
Storage Medium: |
Saturated Steam |
Product Description
SINOMAC autoclave could be used to make hollow block bricks for building and construction. Size and Speficication could be standard or customized to meet differernt customers' requirements.
1. Structure Overview
The major part of the equipment consists of assembly body, lid device, pendulous device , safety device, support, lid insulating layer, sealing arrangement, pipeline valve and meter, etc. The accessories include drainage, electrical control system and safety interlocks. 1.Swing device | 2.Lid device (insulated ) | 3.Manual reducer |
4.Autoclave body | 5.Rail device | 6.Middle support |
7.Movable support | 8.End support | 9.Movable support base plate |
10.End support base plate | 11.Movable support use roller | 12.End support use roller |
13.Movable support use fin | 14.End support use fin | 15.Movable support plate |
16.End support plate | 17.Limited plate | 18.Limited stop iron |
19.Spring | 31.Foundation bolt M24×500 | 32.Nut M24 |
33.Washer 24 | 34.Washer 14 | 35.Circlips for shaft 15 |
36.Oil cup | 37.Drainage cover | |
1.1 Assembly body.
It refers to the whole part of barrel and body flange welded. The 40 teeth equally distributed around the body flange are meshed with the 40 relevant teeth distributed on the lid flange. The bottom of the autoclave lays track, which used to run or park trolley car. The outside of the body is fixed with different tube socket and joint chair, which used for admission and exhaust of steam, exhausting condensed water and installing different meters and valves.
1.2 Lid device.
It is welded by lid flange, bevel plate and dome. The lid is lifted on the top of body by handle and brachyaxis and is able to turn round freely. The opening and closing of the autoclave is through the meshing of the 40 teeth around the lid flange and 40 teeth around the body flange.
1.3 Swing device.
It consists of spindle, cantilever, support plate, roller plate, counterweight, etc. It is installed on the top of autoclave and connects with the lid handle through the counterweight, playing a role in overhanging and turning round the lid device.
1.4 Safety device.
It is fixed to the side of the body and consists of safety handle, base, extension bar and ball valve. When the lid closed, safety handle turns horizontal to lock the lid and the exhaust ball valve closes at the same time. When opening the lid, operator turns safety handle to vertical and the ball valve opens. In order to avoid danger, the lid can be opened only after all of the residual air is exhausted through ball valve.
1.5 Support.
It is used to support the body and can be divided as fixed support, mobile support and end support. In order to adapt to the need of body expansion, except the middle support fixed, the others can move axially along the body with the help of pin roller.
1.6 Lid insulating layer.
It mainly consists of insulating materials, framework, and guard board, preventing the heat losing when autoclave is on operation. (Users can decide the thickness of the insulating material according to its properties.)
1.7 Sealing arrangement.
It consists of seal ring, stop valve and admission elbow. Seal ring is inlaid in the sealing groove of the body flange. In the section of the pressure boosting, external supply of steam enters into the seal groove through elbow and valves, putting pressure on the seal ring to seal lid end face. When it reaches to the rated pressure, the autoclave sealed with the pressure its own through elbow.
1.8 Valves and instructments.
It consists of pressure gage, safety valve, thermal resistance, ball valve, pressure transmitter, zero-pressure controller, assuring the safe operation autoclave.
1.9 Drainage.
It plays a role of exhausting condensed water and consists of drainage pipeline connector, steam trap, blow-down valve. It connects with the flange in the bottom of autoclave. The condensed water is continuously exhausted through steam trap after sedimentation in the connector. Blow-down can exhaust condensed water and sludge non-scheduled.
1.10 Electric control cabinet.
It consists of pressure indicator, temperature indicator, pressure warning unit (interlock control indicator), assuring the safety operation of the autoclave.
1.11 Steam-electricity safety interlocks.
It consists of control cabinet, pressure controller, reducer locking device assembly, assuring the safety operation of the autoclave.(Only when the door is put in the precalculated position, safety handle is turned to horizontal direction and the electromagnetic lock is locked, the admission of the steam is allowed. Only when the inner pressure is exhausted below the security level, the ball valve is allowed to open and electromagnetic lock is allowed to unlock and then the autoclave door is enable to open. During the section of closing door and boosting, if there is one door not put in place or the electromagnetic lock is not locked, the "lid is not closed" indicator light turns on, at the same time the bell rings to warn operators when the pressure is boosted to a index value after admission of steam.)
2. Technical Monopoly
2.1 Autoclave of hydraulic automatic opening-door device (ZL 2011 2 0025592.4)
2.2 Posses autoclave of automatic door operator (ZL 2011 2 0025674.9)
2.3 Worktable of cutting kettle tooth (ZL 2011 2 0025738.5)
2.4 The pressure drainage device of autoclave (ZL 2011 2 0025595.8)
2.5 Electrical safety interlock device of autoclave (ZL 2011 2 0026871.2)
3. Production Technology
3.1 After welding the door, it must be proceed annealing heat treatment.
3.2 Polish toothed cutter of flange of autoclave body, and carry out magnetic particle testing.
3.3 Use double scale container board, and ensure the longitudinal joint of each section.
3.4 Carry out the physical and chemical test (stretch, impact), ensure its strength.
3.5 Welds are 100% X-ray detection, then carry out hydraulic test of 2.1MPa after passing.
The whole process is complete inspected by CSEI factory inspection, and leave factory after stamp and signature.
4. Safety Interlocking Protection
4.1 Manual reducer has mechanical interlocking, and operator can not rotate it when the autocalve has pressure inside.
4.2 It has a manual limit safety interlocking device. Blocking the door manually and when it is unlocked, we can open the door.
4.3 It has an electric limit safety interlocking device. It works with item 4.2 and connects with electric cabinet. When rotating it with pressure, sound-light alarm will happen.
5. Autoclave Specification Item | Name | Unit | Ø1.65×L | Ø2.0×L | Ø2.5×L | Ø2.68×L | Ø2.85×L | Ø3.0×L | Ø3.2×L | Ø3.5×L |
1 | Inner dia. | m | 1.65 | 2 | 2.5 | 2.68 | 2.85 | 3 | 3.2 | 3.5 |
2 | Length | m | According to user's requirement |
3 | Design pressure | Mpa | 1.6 |
4 | Design temp. | ºC | 204 |
5 | Working pressure | Mpa | 1.5 |
6 | Working temp. | ºC | 201 |
7 | Shell thickness | mm | 14 | 16 | 20 | 20/26 | 20/26 | 20/26 | 22/26 | 22/26 |
8 | Main material | | Q345R-GB713,16MnII-NB/T47008,20-GB/T8163,20-GB9948 |
9 | Structure type | Single door or double doors |
10 | Medium | | Saturated steam amd condensed water |
11 | Inside rail | mm | 600×200 | 600×150 | 800×200 | 800×250 | 1220×320 |
12KG | 12KG | 15KG | 24KG | 38KG |
12 | Door opening | | Manual,electrical,hydraulic pressure,pneumatic swing-up door or side-opening door |
6. Professional Workshop
From SINOMAC team with powerful design and development capabilities.
Changzhou Sinomac Machinery Technology Co. Ltd. Is located in the hometown of autoclave, Changzhou, Jiangsu Province. It is specialized in providing energy efficient autoclave, corollary equipments for production line, and projects of intelligent production. The autoclave developed and produced by our company is in a leading role in domestic market, and it is widely used in many different areas, such as composites curing, safety glass laminating, photovoltaic module encapsulation, wood carbonization, rubber vulcanization, industry chemicals synthetisis, and so on.
We focus on satisfying different needs from global customers. All the products can be produced according to ASME, PED, AD-2000 standards, and we will also provide relevant certificate and code to make sure its quality and safety. At present, our autoclave has been sent to America, Canada, Russia, Australia, New Zealand, France, Brazil, Venezuela, Saudi Arabia, and Tunis.
We are concerned of the added value of customer's future use, manufacturing human and intelligent equipment, and we always try our best to meet customer's demands, and provide best service on the basis of customer's investment maximization. At the same time, we also focusing on the stability, efficiency, and energy-saving of products to make sure customer can get a stable, sustainable, and profitable business growth from the investment in our equipment.